Fronius Backup Controller 3P-35A
Note: Suitable for 3-phase grids where neutral conductor disconnection is not required. Use is only permitted after enquiry and approval by the network operator.
The Fronius Backup Controller is a stationary switching unit that enables automatic transition to full backup mode and is designed for use in public grids with TN-C-S/TN-S systems. Its main function is to automatically and safely disconnect all connected consumers and generators from the public grid in the event of a grid outage or disturbance, in accordance with the grid operator's requirements. This solution ensures that the entire household is always safely supplied, as long as sufficient energy is available from the PV system or battery storage – even when no one is home. Once grid stability is restored, the consumers and generators are automatically reconnected to the public grid.
Features:
- Automatic solution for maximum safety
- 3- and 4-pole variant
- Automatic return to normal operation
- Cable- and space-saving DIN rail mounting in the distribution cabinet
Technical Data: | |
Manufacturer's Part Name: | Backup Controller 3P-35A |
Compatibility: | Primo & Symo GEN24 Plus1) |
Switching: | Automatic |
Dimensions (W x H x D): | 144 x 100 x 65.6 mm |
1)The Full Backup emergency power option is not available for the Fronius Symo GEN24 3.0-5.0 Plus.
For more information, please refer to the data sheet.
Fronius International GmbH
Froniusstraße 1
4643 Pettenbach
Österreich
contact@fronius.com
www.fronius.com
Fronius Deutschland GmbH
Fronius Straße 1
36119 Neuhof-Dorfborn
Deutschland
pv-sales-germany@fronius.com
www.fronius.com/de-de
Safety Instructions:
1. Installation by Professionals: The installation should only be carried out by qualified and authorized professionals.2. Wear Protective Equipment: When handling PV modules, use appropriate protective equipment such as gloves and safety glasses.
3. Components must operate within the technical specifications listed in their data sheets.
4. Use only manufacturer-approved accessories.
5. Do not install components if they are physically damaged or equipped with damaged or substandard cables or connectors.
6. No Work Under Voltage: Perform installation or maintenance work only when the system is de-energized.
7. Do not apply an external voltage source to a module or a string with components.
8. Protection from External Influences: Install protective conduits and cables in a way that shields them from UV radiation, rodents, and mechanical damage.
9. Protection from Moisture and Dirt: Store and install accessories in dry and clean locations to prevent damage from moisture or contamination.
10. Regular Inspection: Inspections and maintenance should be carried out regularly to detect potential damage or signs of aging at an early stage.