Fronius IG Sensor Card Retro 4,240,004,Z
Mit der Fronius Sensor Card / Box können bis zu sechs Sensoren zur Messung der Einstrahlung, Umgebungstemperatur, Modultemperatur, Windgeschwindigkeit usw. in das Fronius DATCOM-System integriert werden. Bereits mit Einstrahlung und Modultemperatur kontrollieren Sie Ihr PV-System und können Abweichungen in der Anlagenleistung schneller entdecken und die Performance auf konstant hohem Niveau halten. 947 / 5.000 Übersetzungsergebnisse Übersetzung
Fronius IG Sensor Card Retro
With the Fronius Sensor Card / Box, up to six sensors for measuring irradiation, ambient temperature, module temperature, wind speed, etc. can be integrated into the Fronius DATCOM system. You can control your PV system with the irradiation and module temperature and can detect deviations in system performance more quickly and keep performance at a consistently high level. In addition to the sensor card/box, a Fronius data manager is required to evaluate the data. This is either standard in the inverter or can easily be retrofitted.
| Technical data | |
| Manufacturer number: | 4,240,004,Z |
| Weight: | 0.3 kg |
Please see the data sheet for further details.
Fronius International GmbH
Froniusstraße 1
4643 Pettenbach
Österreich
contact@fronius.com
www.fronius.com
Fronius Deutschland GmbH
Fronius Straße 1
36119 Neuhof-Dorfborn
Deutschland
pv-sales-germany@fronius.com
www.fronius.com/de-de
Safety Instructions:
1. Installation by Qualified Personnel: The installation of smart meters must only be carried out by qualified electricians or authorized professionals.2. Power Circuit Disconnection: Before installation, the power circuit into which the smart meter will be integrated must be completely disconnected and checked for powerlessness.
3. Ensure Proper Grounding: Verify the proper grounding of the system before connecting the smart meter.
4. Select Installation Location: Install the device only in a safe, well-ventilated, and dry indoor area that meets the manufacturer's installation requirements.
5. Correct Cable Connection: Use only manufacturer-recommended cables and connections, ensuring correct polarity and secure contacts.
6. Danger from High Voltages: Smart meters are integrated into power circuits that may be live. Avoid any contact with open connections or wires.
7. Use Proper Circuit Protection: Connect the smart meter only to power circuits with appropriate protective switches (e.g., residual current devices (RCDs) or circuit breakers).
8. Check Insulation: Inspect cable insulation and connection status before commissioning to avoid short circuits.
9. No Modifications: Do not alter or modify the smart meter or its wiring.
10. Avoid Overloading: Do not exceed the manufacturer's specified maximum current load for the smart meter.
11. No Unauthorized Modifications: Unauthorized alterations, modifications, repairs, or opening of the product are strictly prohibited.