- Delivery time:
- Order number: 114231
- Weight: 116.962 kg
- Collection possible: Baunatal
in stock (2-5 working days) (abroad may vary)
Fronius Reserva 6.3 + Symo GEN24 8.0 Plus incl. Smart Meter IP and SPD Type 1+2
Please note that complete sets can only be shipped in full if all components are available. Partial shipping is unfortunately not possible.
The Fronius storage system, consisting of the Reserva 6.3, the Fronius Symo GEN24 8.0 Plus hybrid inverter including Smart Meter TS 65A-3 and surge protection device (SPD) Type 1+2, is the ideal solution for system operators aiming to increase their self-consumption. Reserva is Fronius' new PV storage solution. The efficient DC-coupled high-voltage battery ensures the storage of solar energy with minimal losses. Flexibly expandable with two to five modules and a capacity ranging from 6.3 to 15.8 kWh, it is perfectly matched to Fronius hybrid inverters. Thanks to lithium iron phosphate (LFP) technology, it also offers high safety and a long service life. Together with the Fronius Symo GEN24 8.0 Plus, designed for both on-grid and backup power operation, the system includes a powerful hybrid inverter that comes standard with WLAN and Ethernet connectivity, and allows easy integration of third-party components. The Fronius Smart Meter IP acts as the intelligence of the system and monitors, optimizes and controls the energy flow in the household. Together with Fronius Solar.web, the Fronius Smart Meter IP provides a clear display of personal electricity consumption. The surge protection device protects the PV system from damage caused by overvoltage and is delivered as a retrofit kit that can be installed in the inverter’s connection area within minutes.
Features:
- Flexible high-voltage storage Fronius Reserva 6.3: Modular design with 6.31 kWh capacity, safe and long-lasting thanks to LFP technology, perfectly matched to Fronius hybrid inverters
- The most powerful GEN24 hybrid inverter Fronius Symo GEN24 8.0 Plus: Efficient energy conversion and distribution, suitable for backup power operation and Multi-Flow Technology
- Precise energy consumption management thanks to Smart Meter IP (incl. current transformers): Real-time monitoring and optimization of energy flow for maximum efficiency and cost-effectiveness
- Surge protection Type 1+2 for direct and indirect lightning strikes for use with Fronius GEN24 inverters
Technical Data | |
Battery Model Name: | Reserva 6.3 |
Battery Module: | Reserva 3.15 kWh |
Number of Battery Modules: | 2 |
Usable Capacity [1]: | 6.31 kWh |
Cell Technology: | Lithium Iron Phosphate (LFP) |
Inverter Model Name: | Fronius Symo GEN24 8.0 Plus |
Number of MPP Trackers: | 2 |
AC Nominal Power: | 8000 W |
Max. Output Power: | 8000 VA |
Max. DC Input/Output Power (Battery Connection) | 8260 W |
Max. Charging Power with AC Coupling (Battery Connection) | 8000 W |
Smart Meter Model Name: | Smart Meter IP (incl. current transformers) |
For further details, please refer to the attached data sheets.
Fronius International GmbH
Froniusstraße 1
4643 Pettenbach
Österreich
contact@fronius.com
www.fronius.com
Fronius Deutschland GmbH
Fronius Straße 1
36119 Neuhof-Dorfborn
Deutschland
pv-sales-germany@fronius.com
www.fronius.com/de-de
Sicherheitshinweise:
1. Installation durch Fachpersonal: Die Installation eines PV-Speichersystems darf ausschließlich von qualifizierten Fachkräften durchgeführt werden.2. Belüftung sicherstellen: Installieren Sie den Speicher in einem gut belüfteten Bereich, um die Wärmeableitung zu gewährleisten und die Gefahr einer Überhitzung zu vermeiden.
3. Brandschutz beachten: Batteriespeicher sollten in sicherem Abstand zu brennbaren Materialien installiert werden.
4. Zugänglichkeit sicherstellen: Installieren Sie den Speicher an einem leicht zugänglichen Ort, um eine sichere Wartung und Notabschaltung zu ermöglichen.
5. Mechanische Sicherheit: Achten Sie darauf, dass der Batteriespeicher sicher befestigt und gegen Umkippen geschützt ist.
6. Gefahr durch hohe Spannungen: Batteriespeicher können gefährlich hohe Spannungen erzeugen. Vermeiden Sie den Kontakt mit offenen Anschlüssen oder Leitungen.
7. Polung beachten: Stellen Sie sicher, dass die Anschlüsse korrekt polarisiert sind, um Kurzschlüsse und Schäden zu vermeiden.
8. Geeignete Kabel und Sicherungen: Verwenden Sie nur vom Hersteller empfohlene Kabel, Anschlüsse und Sicherungen.
9. Erdung: Sorgen Sie dafür, dass der Speicher und das gesamte PV-System ordnungsgemäß geerdet sind.
10. Kurzschlüsse vermeiden: Halten Sie Werkzeuge, Drähte oder andere leitende Gegenstände fern von den Anschlüssen des Speichers.
11. Ordnungsgemäßer Gebrauch: Verwenden Sie den Speicher nur für den vorgesehenen Zweck und unter den spezifizierten Bedingungen.
12. Fachgerechte Entsorgung: Batterien enthalten umweltgefährdende Stoffe und müssen gemäß den geltenden Vorschriften für Elektroschrott recycelt oder entsorgt werden.
13. Gefahr durch Restladung: Beachten Sie, dass Batterien auch nach dem Abschalten gefährliche Restladungen führen können.
14. Keine Modifikationen: Unerlaubte Veränderungen, Umbauten oder Reparaturen sowie das Öffnen des Produktes sind verboten.