- Delivery time:
- Order number: 113238
- Weight: 25 kg
- EAN: 4262431421977
- Manufacturer's no.: ETU0010-09-00P
in stock (2-5 working days) (abroad may vary)
GoodWe GW10K-ET PLUS+ hybrid inverter ET-Series
GW10K-ET PLUS+ (+DCSWITCH/WIFI/3P-METER/BACKUP)
GoodWe's ET-plus series offers three-phase hybrid inverters for high-voltage batteries, which enable even more independence in energy supply and maximize self-consumption through intelligent control of loads and higher charging and discharging performance. The ET-plus series has a power range of 5 kW, 6.5 kW, 8 kW and 10 kW and is 100% unbalanced load capable. It also has a back-up function with an uninterrupted switching time. The new ET series is equipped with a dry contact, which allows control of the operation of loads such as heat pumps and electric vehicle chargers.
Highest security standards
- Integrated surge protection type II on the DC side
- Protection class IP66
Optimized energy autonomy
- Wide battery voltage range
- Supports dynamic active power limitation and load visualization
Smart and efficient operation
- 100 % unbalanced load capability for self-consumption and emergency power operation. Support smart home interactions
Specifications
Input (PV-DC) | |
Max. PV generator power: | 13000 Wp |
Max. Input Voltage1): | 1000 V |
MPP voltage range: | 200 ~ 850 V |
Rated input voltage: | 620 V |
min Supply Voltage1): | 210 V |
Max. Input current per MPP tracker | 12.5 A |
Max. Short-circuit current per MPP tracker | 15.2 A |
Number of independent MPP inputs / Strings per MPP input: | 1 / 1 |
Nominal apparent power to the utility grid: | 10000 VA |
Max. Output current to utility grid: | 3 x 16.5 A |
Battery Data | |
Battery type: | Li-Ion |
Battery Voltage: | 180~600 V |
Max. Charge/Discharge Current: | 25 A |
Backup Data | |
Time to switch to emergency mode: | < 10 ms |
Rated output power: | 10000 VA |
Peak power output2): | 16500 VA, 60 sec |
General Data | |
Dimensions (W / H / D): | 415 x 516 x 180 mm |
Weight: | 24 kg |
Operating temperature range: | -35 ~ 60 °C |
Noise emission (normal case): | < 30 dB |
Communication: | RS485, WiFi, CAN |
1)For a 1000 V system, the maximum operating voltage is 950 V.
2) If no battery is connected, the inverter only starts feeding when the phase voltage is higher than 400 V.
For more information, please refer to the data sheet.