€1,207.38
% Was: Regular price: €1,897.30 ¹ (36.36% saved)
- Delivery time:
No longer available
- Item-No.: 113909
- GTIN: 4262431423889
- Manufacturer-No.: ETU0010-09-01P
- Product-Weight: 29 kg
- Shipping info: Paket
GoodWe GW10KN-ET+ PLUS 16A Hybrid Inverter 10 kW
Smart meter and current transformer are already included in the scope of delivery
The ET-PLUS+ 16A series from GoodWe offers three-phase hybrid inverters for high-voltage batteries, including GoodWe's own batteries and batteries from manufacturers such as BYD and LG Energy Solution. The ET-PLUS+ 16A series enables the connection of module strings with up to 16 A and is thus prepared for the next generation of solar modules. The series was developed to maximize energy yield, optimize self-consumption, absorb peak loads and provide emergency power supply. The emergency power supply shines with astonishing switching times of less than 10 milliseconds and is therefore state of the art. The power classes of the inverters are 5 kW, 6.5 kW, 8 kW or 10 kW and are 100% capable of handling unbalanced loads. The new ET series is equipped with a potential-free contact, which enables the control of the operation of loads such as heat pumps and charging devices for electric vehicles.
Features:
- Overvoltage protection on AC and DC side
- Integrated emergency power with uninterruptible switching < 10 ms
- Protection class IP66
- Programmable potential-free contact for smart home interactions
| Technical data: | |
| Inverter type: | Hybrid inverter |
| Feed-in: | Three-phase |
| Output power | 10 kW |
| Number of MPP trackers: | 2 |
| Number of PV strings per MPPT: | 1/1 |
| Overvoltage protection: | DC type II / AC type III |
| Manufacturer name: | GW10KN-ET PLUS+ |
| Dimensions (L x W x T): | 415 x 516 x 180 mm |
For further information please refer to the data sheet.

10 a.m. - 12 p.m. and
2 p.m. - 4 p.m.
- Photovoltaic experts since 2008
- Only original products from top brands
- Short response times to inquiries
- 2% discount for prepayment
- Short delivery times
- Collection of in-stock items possible
Login
Safety Instructions:
- Installation by qualified personnel: Installation must only be carried out by qualified electricians or other qualified personnel.
- Work with the system switched off: Switch off all power sources (AC and DC) and verify that the system is de-energized before installation.
- Ensure grounding: The inverter and the entire system must be properly grounded to ensure safety.
- Ensure ventilation: Install the inverter in a well-ventilated location to prevent overheating. Observe the minimum clearances recommended by the manufacturer.
- No contact with flammable materials: The inverter must not be installed near flammable or explosive materials.
- High voltage hazard: Inverters operate at high DC and AC voltages. Do not touch any exposed wires or connectors.
- Use correct cables: Use only cables and connectors recommended or certified by the manufacturer.
- Observe polarity: Ensure the DC side is connected with correct polarity to avoid damage to the device.
- Do not work while connected: Never open or work on the inverter while it is live.
- Install surge protection: Protect the inverter and system from surges by installing surge protection devices and appropriate fuses.
- Ensure the device is de-energized: Before any maintenance or repair, all power sources must be disconnected and verified to be de-energized.
- No modifications: Unauthorized alterations, modifications, or repairs, as well as opening the product, are prohibited.
- Protect from water and moisture: Install the inverter in an environment protected from rain, condensation, and high humidity.
- Avoid dust and contamination: Keep the inverter free from dust, insects, and other contaminants.