| Quantity | Unit price |
|---|---|
| From 8 | €100.37 |
| From 10 | €92.34 |
| From 20 | €88.33 |
| From 35 | €84.31 |
- shipping note: bulky goods Delivery time:
- Order number: 114557
- Weight: 24.5 kg
- Manufacturer's no.: LD16970
- Collection possible: No collection possible.
in stock (7-14 working days) (abroad may vary)
Luxor Eco Line Pro 465 Wp TOPCon Double Glass Full Black Solar Panel LD16970
With the Luxor Eco Line Pro, Luxor Solar presents a Full Black double glass solar panel of the latest generation – based on the modern N-Type TOPCon technology and designed for the highest demands on performance and aesthetics. 465 watts peak output and a module efficiency of up to 23.60 % make this panel one of the most powerful options in the Full Black segment. Whether overcast skies, early morning or evening light – the Eco Line Pro delivers electricity reliably.
The fully black design – black cells, black frame, black front – blends aesthetically and unobtrusively into any roof. At the same time, the glass-glass construction ensures maximum robustness: instead of a plastic film on the back, a second pane of glass is used – better protected against moisture, UV radiation and mechanical stress, with a considerably longer service life than conventional panels.
The Eco Line Pro is Luxor Solar's premium solution for projects with a clear long-term perspective and the highest requirements for reliability and durability. High-quality materials and optimised module design minimise degradation and ensure consistently high energy yields – even under demanding environmental conditions. As a German warrantor, Luxor Solar backs the warranty directly under German law – with a 30-year product warranty, a 30-year linear performance warranty and a guaranteed output of at least 89 % after 30 years. Maximum investment security throughout the entire system lifetime.
What is TOPCon Technology?
TOPCon stands for Tunnel Oxide Passivated Contact – a next-generation solar cell technology. An ultra-thin tunnel oxide layer minimises recombination losses within the cell, significantly boosting efficiency compared to older technologies such as PERC. Combined with an N-Type silicon wafer as the base, the cell is inherently PID-free and LID-free – ensuring stable performance throughout the entire service life.
What are PID and LID?
PID (Potential Induced Degradation) refers to a loss of output caused by high voltages within the solar system. Tiny leakage currents flow through the panel and damage the cells – a process accelerated by moisture and heat. LID (Light Induced Degradation) is a one-time, minor drop in output that occurs directly after commissioning, when the panel experiences its first hours of sunlight.
In the Luxor Eco Line Pro, both effects are largely eliminated thanks to the modern N-Type TOPCon cell architecture. N-Type cells are inherently far less susceptible to these degradation effects than conventional P-Type cells – meaning more stable performance and higher yields throughout the entire panel lifetime.
Features:
- 465 Wp output & up to 23.60 % efficiency – one of the most powerful Full Black options on the market
- Full Black double glass construction – maximum aesthetics meets maximum robustness
- PID-free & LID-free – stable performance thanks to N-Type TOPCon cell technology
- Hail Class 4 – certified up to 45 mm hailstone diameter / 110.5 km/h
- 30-year product & performance warranty – under German law, min. 89 % output after 30 years
| Technical Data | |
| Module Type / Cell Technology: | Glass-Glass Solar Panel / Monocrystalline N-Type TOPCon |
| Rated Power (STC): | 465 Wp |
| Module Efficiency: | 23.60 % |
| Glass Front / Rear: | 2.0 mm solar glass with anti-reflective coating, black / 2.0 mm semi-tempered glass, white |
| Frame: | Stable anodised aluminium profile, black |
| Dimensions: | 1762 × 1134 × 30 mm |
| Connector Type: | MC4 or equivalent (IP67) |
| Hail Class: | Class 4 (ca. 45 mm / 110.5 km/h) |
| Mechanical Load: | 6,000 Pa (snow load) / 4,000 Pa (wind load) |
| Warranty: | 30-year product warranty / 30-year performance warranty |
Further technical details can be found in the datasheet.
LUXOR SOLAR GmbH
Kornbergstraße 29
70176 Stuttgart
Deutschland
www.luxor.solar
info@luxor-solar.com
LUXOR SOLAR GmbH
Kornbergstraße 29
70176 Stuttgart
Deutschland
www.luxor.solar
info@luxor-solar.com
Safety Instructions:
1. Installation by Professionals: Installation should only be carried out by qualified and authorized professionals.2. Use of Protective Equipment: When handling PV modules, wear appropriate protective equipment such as gloves and safety goggles.
3. Secure Work Area: Do not work in adverse weather conditions, particularly rain, snow, or strong winds.
4. Use Covering: Cover the modules during installation to minimize power generation.
5. Fastening and Load Capacity: Ensure that the substructure can safely support loads from wind, snow, and other environmental factors.
6. Contact Protection: Do not touch exposed electrical contacts or cable ends.
7. No Handling with Wet Hands: Never work with electrical connections or components if your hands are wet.
8. Use Appropriate Tools: Use insulated tools and measure the voltage of the modules before making connections.
9. Grounding: Ensure that the system is properly grounded to avoid electric shocks or overvoltage damage.
10. No System Modifications: Do not modify the system without consulting a professional or the manufacturer.