€12,902.39
- Delivery time:
Currently out of stock, delivery time: 105-107 working days
- Item-No.: 114239
- Product-Weight: 1015.052 kg
- Shipping info: Spedition
PV Complete Set 16 kWp - 36x Trina 455 Wp + Fronius Symo GEN24 Plus SC 12.0 + Reserva 15.8
Features:
- Ready-to-use 16 kWp complete PV set with storage system and accessories from leading manufacturers
- Trina Solar Vertex S+ solar modules - Up to 455 W peak power, 22.8 % module efficiency with high-density cell connection technology
- Flexible Reserva 15.8 high-voltage storage system: Modular design with 15.79 kWh capacity, safe and durable thanks to LFP, perfectly matched to Fronius hybrid inverters
- Powerful three-phase hybrid inverter Fronius Symo GEN24 Plus SC 12.0: Efficient energy conversion and distribution, suitable for emergency power operation and multi-flow technology (including type I+II surge protection)
- Precise energy consumption management thanks to the Smart Meter IP: real-time monitoring and optimization of the energy flow for maximum efficiency and economy
Package Includes:
- 36x Trina Solar Vertex S+ Solar Panels TSM-455NEG9R.28
- 1x Fronius Symo GEN24 12.0 Plus SC Hybrid Inverter
- 1x Fronius Reserva 15.8 Battery Storage 15,79 kWh
- 1x Fronius Smart Meter IP incl. Current Transformers
- 1x Fronius Surge Protection Typ 1+2 for GEN24 Inverters
- 4x Trina TS4 / Plug and Socket in a set 4-6mm² / TS4-M1 & TS4-F1
- 1x KBE Solar Cable 6 mm² DB+ EN 50618 H1Z2Z2-K, 100 meters
| Technical Specifications | |
| Manufacturer Designation Solar Modules: | TSM-455NEG9R.28 |
| Module Type: | Glass/Glass white backsheet |
| Nominal Power (STC): | 455 Wp |
| Manufacturer Designation Battery: | Reserva 12.6 |
| Battery Module: | Reserva Battery Module 3.15 kWh |
| Number of Battery Modules: | 5 |
| Usable Capacity [1]: | 15.79 kWh |
| Cell Technology: | Lithium Iron Phosphate (LFP) |
| Manufacturer Designation Inverter: | Fronius Symo GEN24 12.0 Plus SC |
| Number of MPP Trackers: | 2 |
| AC Nominal Power: | 12000 W |
| Max. Output Power: | 12000 VA |
| Max. DC Input/Output Power (Battery Connection): |
11682 W |
| Max. Charging Power with AC Coupling (Battery Connection): |
11682 W |
| Manufacturer Designation Smart Meter: | Smart Meter IP |
| PV Connector: | Trina TS4 |
| Solar Cable: | 100m, 6 mm², black |
Please refer to the attached data sheets for further details.
Manufacturer Solar Modules/PV Connector:
Trina Solar Co., LtdNo.2 Tianhe Road,
Trina PV Industrial Park, Xinbei District, Jiangsu
China
sales@trinasolar.com
https://static.trinasolar.com
Economic Operator Solar Modules:
Trina Solar (Germany) GmbHWerner-Eckert-Straße 4,
81829 Munich,
Germany
EUservice@trinasolar.com
https://static.trinasolar.com/de
Manufacturer Inverter / Battery Storage / Smart Meter:
Fronius International GmbHFroniusstraße 1
4643 Pettenbach
Austria
contact@fronius.com
www.fronius.com
Manufacturer Solar Cable:
KBE Elektrotechnik GmbHSymeonstraße 8
12279 Berlin
Germany
info@kbe-elektrotechnik.com
www.kbe-elektrotechnik.com

10 a.m. - 12 p.m. and
2 p.m. - 4 p.m.
- Photovoltaic experts since 2008
- Only original products from top brands
- Short response times to inquiries
- 2% discount for prepayment
- Short delivery times
- Collection of in-stock items possible
Login
Safety Instructions:
1. Installation by Qualified Personnel: The installation and commissioning of the PV system must be carried out by qualified professionals to ensure safety and proper functionality.2. Compliance with Regulations: National and local building regulations, safety standards, and environmental protection regulations must be observed.
3. Ensure Power Disconnection: Before working on the system, ensure that all circuits are de-energized. Always wear appropriate protective clothing and use insulated tools.
4. Grounding and Potential Equalization: The entire system must be properly grounded, and potential equalization must be established according to applicable regulations.
5. Hazard from High DC Voltage: Solar modules generate high DC voltages, even in diffuse light. Avoid contact with open connections and cables.
6. Safe Handling of PV Storage Systems: Install and maintain battery storage systems only according to the manufacturer's instructions. Ensure proper ventilation and protection against overheating.
7. Fire Hazard Prevention: Ensure proper connection work and use only approved cables, PV connectors, and fuses.
8. Protection from Moisture: All electrical connections must be protected from moisture and water. Use appropriate seals and protective covers.
9. Child Safety: Keep children and unauthorized persons away from the system. The battery storage and inverter areas must be secured.
10. Smart Meter and Communication Units: Ensure that communication devices for system operation are securely installed and protected against voltage spikes.
11. Regular Maintenance: Have the system regularly inspected by qualified personnel to ensure safe operation. An annual visual inspection of the modules, cables, and connections is recommended.
12. Use of Original Accessories: Use only manufacturer-recommended accessories to ensure the safe operation of the system.