SMA SUNNY TRIPOWER X 12-50, STP 12-50 Solar Inverter
The new Sunny Tripower X is the innovative system solution for commercial and large home PV systems. The integrated System Manager function with direct access to Sunny Portal powered by ennexOS monitors up to five SMA inverters and one energy meter. This enables the dynamic closed-loop control of active and reactive power via SMA Dynamic Power Control. Thanks to the wide input voltage range and the high input current capability, it is compatible with the latest generation of high-performance PV modules. The innovative enclosure design ensures efficient cooling of the electronic components and thus guarantees maximum lifetime of the Sunny Tripower X.
Commissioning can be performed quickly and easily as well as centrally for all devices in the system. During operation, users benefit from integrated software solutions: SMA ShadeFix increases PV yields even in the event of partial shading, while SMA ArcFix detects electric arcs effectively and can reliably reduce the risk of fire.
Integrated system manager
- Monitoring and control for up to 5 inverters included
- Direct access to Sunny Portal powered by ennexOS
Maximum yields
- Yield increase through integrated SMA ShadeFix
- SMA Smart Connected
More flexibility
- 3 MPP trackers
- 150 % overdimensioning
- High input current for highperformance PV modules
Safety included
- SMA ArcFix arc-fault circuit interrupter
- DC overvoltage protection (option)
Technical data
Input (PV-DC) | |
Max. PV generator power: | 18000 Wp |
Max. input voltage: | 1000 V |
MPP voltage range: | 206 V bis 800 V |
Rated input voltage: | 570 V |
Min. input voltage / initial input voltage: | 150 V / 188 V |
Max. input current per MPP tracker: | 24 A |
Max. short-circuit current per MPP tracker: | 35 A |
Number of independent MPP trackers / strings per MPP tracker: | 3 / 2 |
Output (AC) | |
Rated power (at 230 V, 50 Hz) : | 12000 W |
Max. apparent power: | 12000 VA |
Nominal AC voltage: | 3/N/PE; 220 V / 380 V 3/N/PE; 230 V / 400 V 3/N/PE; 240 V / 415 V |
Voltage range: | 176 V bis 275 V 304 V / 477 V |
Grid frequency / range: | 50 Hz / 44 Hz bis 56 Hz |
Rated grid frequency / rated grid voltage: | 50 Hz / 230 V |
Rated output current: | 3 x 17,4 A |
Max. output current: | 3 x 36,6 A |
Power factor at rated power / adjustable displacement power factor: | 1 / 0.8 overexcited to 0.8 underexcited |
Feed-in phases / AC connection: | 3 / 3-(N)-PE |
Efficiency | |
Max. efficiency / European efficiency: | 98,3 % / 97,7 % |
General data | |
Dimensions (W / H / D): | 728 mm / 762 mm / 266 mm (28.7 inch / 30.0 inch / 10.5 inch) |
Weight: | 35 kg (77 lb) |
Operating temperature range: | -25 °C to +60 °C (-13 °F to +140 °F) |
Noise emission, maximum (1 m): | < 65 dB(A) |
Energy consumption (night) : | < 5 W |
Topology / cooling concept: | No galvanic isolation / OptiCool |
Protection class (according to IEC 60529) / climate class (according to IEC 60721-3-4): | IP65 / 4K26 |
Permissible maximum value for relative humidity (non-condensing) : | 100% |
For more information, please refer to the data sheet.
SMA Solar Technology AG
Sonnenallee 1
34266 Niestetal
Deutschland
info@SMA.de
www.sma.de
SMA Solar Technology AG
Sonnenallee 1
34266 Niestetal
Deutschland
info@SMA.de
www.sma.de
Sicherheitshinweise:
1. Installation durch Fachpersonal: Die Installation darf nur von qualifizierten Elektrikern oder Fachpersonal durchgeführt werden.2. Arbeiten bei ausgeschaltetem System: Schalten Sie alle Stromquellen (AC und DC) ab und überprüfen Sie die Spannungsfreiheit vor der Installation.
3. Erdung sicherstellen: Der Wechselrichter und das gesamte System müssen ordnungsgemäß geerdet sein, um die Sicherheit zu gewährleisten.
4. Belüftung sicherstellen: Installieren Sie den Wechselrichter an einem gut belüfteten Ort, um Überhitzung zu vermeiden. Halten Sie die vom Hersteller empfohlenen Mindestabstände ein.
5. Kein Kontakt mit brennbaren Materialien: Der Wechselrichter darf nicht in der Nähe von brennbaren oder explosiven Stoffen installiert werden.
6. Gefahr durch hohe Spannung: Wechselrichter arbeiten mit hohen DC- und AC-Spannungen. Berühren Sie keine freiliegenden Drähte oder Anschlüsse.
7. Richtige Kabel verwenden: Verwenden Sie ausschließlich vom Hersteller empfohlene oder zertifizierte Kabel und Steckverbindungen.
8. Polarität beachten: Stellen Sie sicher, dass die DC-Seite korrekt polarisiert angeschlossen ist, um Schäden am Gerät zu vermeiden.
9. Kein Arbeiten bei angeschlossenem Gerät: Öffnen oder arbeiten Sie niemals am Wechselrichter, während er unter Spannung steht.
10. Blitzschutz installieren: Schützen Sie den Wechselrichter und das System vor Überspannungen durch Blitzschutz und geeignete Sicherungen.
11. Spannungsfreiheit sicherstellen: Vor jeder Wartung oder Reparatur müssen alle Stromquellen abgeschaltet und auf Spannungsfreiheit geprüft werden.
12. Keine Modifikationen: Unerlaubte Veränderungen, Umbauten oder Reparaturen sowie das Öffnen des Produktes sind verboten.
13. Schutz vor Wasser und Feuchtigkeit: Installieren Sie den Wechselrichter in einer Umgebung, die vor Regen, Kondensation und hoher Luftfeuchtigkeit geschützt ist.
14. Vermeidung von Staub und Verschmutzung: Halten Sie den Wechselrichter frei von Staub, Insekten und anderen Verunreinigungen.