Prices incl. VAT, plus shipping costs
- Delivery time:
- Order number: 111941
- Weight: 8.1 kg
- EAN: 8033100185126
- Manufacturer's no.: 1008661
- Collection possible: No collection possible.
in stock (2-5 working days) (abroad may vary)
HT Instruments I-V400w
1000V/15A I-V Curve Tracer compatible with HTANALYSIS™
I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems.
- Measurement of I-V Curve of one or more modules or of one whole string up to 1000V/15A
- Measurement of open-circuit voltage and short-circuit current Voc/Isc
- Database of 30.000 selectable photovoltaic modules
I-V400w allows field detection of I-V Curve an of the main characteristic parameters both of a single module and of strings of modules for PV installations up to a maximum of 1000V and 15A. For measuring I-V Curve, I-V400w manages an internal database of the modules, which can be updated at any time by the user and comparison between the measured data with the rated values allows immediately evaluating whether the string or the module fulfills the efficiency parameters declared by the manufacturer. I-V Curve can be measured also by decentralizing measurement of irradiation and temperature by using the optional remote unit SOLAR02, using the radio frequency connection (RF) with the master unit. Also for I-V400w, the display at the end of the test of I-V Curve is a clear indication about the compliance with the specifications declared by the panel manufacturer.
HT Instruments GmbH
Am Waldfriedhof 1b
41352 Korschenbroich
Deutschland
info@ht-instruments.de
www.ht-instruments.de
HT Instruments GmbH
Am Waldfriedhof 1b
41352 Korschenbroich
Deutschland
info@ht-instruments.de
www.ht-instruments.de
Safety Instructions:
1. Do not measure voltages or currents in damp or wet environments.2. Do not use the measuring device in environments containing explosive or flammable gas, materials, vapor, or dust.
3. Do not touch the circuit under measurement when no measurement is being performed.
4. Avoid touching exposed metal parts, unused measurement terminals, etc.
5. Do not perform measurements if you notice any irregularities such as deformations, cracks, leaking substances, or a non-functional display on the measuring device.
6. Exercise special caution due to the risk of electric shock when measuring voltages above 25 V in special environments (courtyards, swimming pools, etc.) and above 50 V in normal environments.
7. Use only original HT accessories.