window.ga=window.ga||function(){(ga.q=ga.q||[]).push(arguments)};ga.l=+new Date; ga('create', 'UA-18276432-3', 'auto'); ga('set', 'forceSSL', true); ga('set', 'anonymizeIp', true); ga('require', 'displayfeatures'); ga('require', 'cleanUrlTracker'); ga('require', 'outboundLinkTracker'); ga('require', 'ec'); var match = RegExp('[?&]gclid=([^&]*)').exec(window.location.search); var gclid = match && decodeURIComponent(match[1].replace(/\+/g, ' ')); if(gclid){ ga('set', 'dimension1', gclid); } ga('send', 'pageview'); ga('set', 'nonInteraction', true); setTimeout("ga('send', 'event', 'read', '20 seconds')", 20000); SolarEdge Electricity Meter SE-WND-3Y400-MB-K2 with 100 A Converter | mg-solar-shop
Inquiry PV Battery Systems
Inquiry Solar System

SolarEdge Electricity Meter SE-WND-3Y400-MB-K2 with 100 A Converter

This product is currently not available.
€311.00

Prices incl. VAT plus shipping costs

    no longer available (abroad may vary)

  • 112316
  • 1.55 kg
  • SE-WND-3Y-400-MB-K2 100A
SolarEdge Energy Meter SE-WND-3Y400-MB-K2 with 100 A transformer with Modbus Connection for... more

SolarEdge Energy Meter SE-WND-3Y400-MB-K2 with 100 A transformer

with Modbus Connection for SolarEdge Installations

  • High accuracy meter readings for production/consumption monitoring
  • Import/Export meter readings for export limitation functionality
  • Small and easy to install - fits in standard electrical panel
  • Supports residential, commercial and utility-size installations
  • Support RS485 120 Ω line termination

Technical Data SE-WND-3Y400-MB-K2
ELEKTRICAL SERVICE
Operating Voltage Range - Line to Neutral / Line to Line:184-264,5 / 320-460 Vac
AC Frequency:50/60 Hz
Grids Supported - Single Phase; Three Phase(1):L / N / PE ; L1 / L 2 / L3 / N / PE
Power Consumption (typ.):1.8 W
 
COMMUNICATION
Supported Communication Interfaces:RS485
Response time:≤1(2)
Default Device ID (Modbus):2
RS485 line termination:120 Ω
 
ACCURACY (@ 25 °C, PF: 1)(3)
1 % - 100 % of Rated CT Current:±1.0%
 
STANDARD COMPLIANCE
Safety:IEC 61010-1, CAN/CSA-C22.2 No. 61010-1-04, IEC 61010-1:2010 (3rd Edition)
Immunity:EN 61326, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11
Emissions:FCC Part 15: Class B, CISPR11: 2009: Class B
Export Limiting Schemes:Engineering Recommendation G100. Issue 1 Amendment 1 2017 by ENA London, UK
 
INSTALLATION SPECIFICATIONS
Dimensions (HxWxD):85 x 153 x 38 mm
Weight:310 g
Enclosure type:High impact, ABS and/or ABS/PC plastic UL 94V-0, IEC FV-0
Operating Temperature Range:-40 bis 75 °C
Relative Humidity (noncondensing):310 g
Protection Rating:Indoor (Outdoor when installed in an outdoor enclosure)
Mounting type:DIN Rail / Wall mount
 
CURRENT TRANSFORMER
Model(4):SE-ACT-0750-100
Rated RMS current:100 A
Dimensions (internal / external):20 x 20 mm / 61 x 60.4 mm

(1) PE (Protective Earth) connection is not required for meter operation
(2) When meter is connected at grid connection point, and when RS485 is used for multiple inverters
(3) Using SE-ACTL-0750 CT models
(4) One current transformer per phase

Weitere Details entnehmen Sie bitte dem Datenblatt.
Related links to "SolarEdge Electricity Meter SE-WND-3Y400-MB-K2 with 100 A Converter"
Viewed