This product is currently not available.
€361.90
Prices incl. VAT plus shipping costs
-
Delivery time:
- Order number: 112607
- Weight: 2.48 kg
- Manufacturer's no.: SE-WND-3Y-400-MB-K2 70A
no longer available (abroad may vary)
SolarEdge Energy Meter SE-WND-3Y400-MB-K2 with 70 A transformer
with Modbus Connection for... more
SolarEdge Energy Meter SE-WND-3Y400-MB-K2 with 70 A transformer
with Modbus Connection for SolarEdge Installations- High accuracy meter readings for production/consumption monitoring
- Import/Export meter readings for export limitation functionality
- Small and easy to install - fits in standard electrical panel
- Supports residential, commercial and utility-size installations
- Support RS485 120 Ω line termination
Technical Data SE-WND-3Y400-MB-K2
ELEKTRICAL SERVICE | |
Operating Voltage Range - Line to Neutral / Line to Line: | 184-264,5 / 320-460 Vac |
AC Frequency: | 50/60 Hz |
Grids Supported - Single Phase; Three Phase(1): | L / N / PE ; L1 / L 2 / L3 / N / PE |
Power Consumption (typ.): | 1.8 W |
COMMUNICATION | |
Supported Communication Interfaces: | RS485 |
Response time: | ≤1(2) |
Default Device ID (Modbus): | 2 |
RS485 line termination: | 120 Ω |
ACCURACY (@ 25 °C, PF: 1)(3) | |
1 % - 100 % of Rated CT Current: | ±1.0% |
STANDARD COMPLIANCE | |
Safety: | IEC 61010-1, CAN/CSA-C22.2 No. 61010-1-04, IEC 61010-1:2010 (3rd Edition) |
Immunity: | EN 61326, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
Emissions: | FCC Part 15: Class B, CISPR11: 2009: Class B |
Export Limiting Schemes: | Engineering Recommendation G100. Issue 1 Amendment 1 2017 by ENA London, UK |
INSTALLATION SPECIFICATIONS | |
Dimensions (HxWxD): | 85 x 153 x 38 mm |
Weight: | 310 g |
Enclosure type: | High impact, ABS and/or ABS/PC plastic UL 94V-0, IEC FV-0 |
Operating Temperature Range: | -40 bis 75 °C |
Relative Humidity (noncondensing): | 310 g |
Protection Rating: | Indoor (Outdoor when installed in an outdoor enclosure) |
Mounting type: | DIN Rail / Wall mount |
CURRENT TRANSFORMER | |
Model(4): | SE-CTML-0350-070 |
Rated RMS current: | 70 A |
Dimensions (internal / external): | 9 x 8.9 mm / 42.4 x 30.5 mm |
(1) PE (Protective Earth) connection is not required for meter operation
(2) When meter is connected at grid connection point, and when RS485 is used for multiple inverters
(3) Using SE-ACTL-0750 CT models
(4) One current transformer per phase
Weitere Details entnehmen Sie bitte dem Datenblatt.