Skip to main content Skip to search Skip to main navigation

SolarLog Base 2000

SolarLog Base 2000 (up to 2000 kWp)

The SolarLog Base 2000 is a powerful, modular data logger and energy management system for large photovoltaic installations up to 2000 kWp (2 MWp). It offers extensive features for monitoring, feed-in management, direct marketing, self-consumption optimization, and plant control — ideal for commercial projects, large installations, or multi-tenant buildings.

With its compact DIN-rail design and flexible interfaces (e.g. Ethernet, 2× RS485 or 1× RS422, USB, S0), the Base 2000 can be easily installed in distribution cabinets or new switchgear. Thanks to a modular licensing structure, you only activate the features your project requires — from basic monitoring to advanced management and marketing functions.

Features:

  • Data logger & energy management for PV systems up to 2000 kWp
  • Monitoring of yield, feed-in, consumption and inverter status
  • Feed-in limitation and power management capabilities
  • Direct marketing & smart energy functions (e.g. self-consumption optimization, load control)
  • Supports many inverters and meters from different manufacturers
  • Interfaces: 2× RS485 or 1× RS422, Ethernet, USB, S0 input
  • Modular licensing — enable only the needed features
  • Easy installation via DIN-rail, compact form factor (3 mod-units wide)

Technical Data
Manufacturer: Solar-Log GmbH
Model: Base 2000
Max. system size: up to 2000 kWp (2 MWp) :contentReference[oaicite:6]{index=6}
Inverter interfaces: 2 × RS485 or 1 × RS422, Ethernet, USB, S0 input :contentReference[oaicite:7]{index=7}
Network / Internet communication: Ethernet (LAN) :contentReference[oaicite:8]{index=8}
Functions (depending on license): Monitoring, feed-in control, direct marketing, smart energy / power management :contentReference[oaicite:9]{index=9}
Mounting: DIN-rail (DIN rail enclosure / control cabinet) :contentReference[oaicite:10]{index=10}
Ask us any question
support agent
Phone: +49 561 / 220 706 0
Monday - Friday:
10 a.m. - 12 p.m. and
2 p.m. - 4 p.m.
Shop with confidence
  • Photovoltaic experts since 2008
  • Only original products from top brands
  • Short response times to inquiries
  • 2% discount for prepayment
  • Short delivery times
  • Collection of in-stock items possible
Confidence built in

Average rating of 4.9 out of 5 stars

4,9 of 5 Stars
Manufacturer "Solar-Log GmbH"
Solar-Log™ offers a comprehensive range of products and services for your solar plant. The proprietary Solar-Log™ product line and the associated Solar-Log WEB Enerest™ online platform enable manufacturer-independent, qualified monitoring and control of solar plants worldwide. With an impressive selection of over 2000 compatible components, Solar-Log™ is a unique system for energy management in the renewable energy sector. The company offers customized services for installers, wholesalers, investors and end customers, including monitoring, grid feeding, energy management and direct marketing of solar power to meet individual requirements.
solarlog datasheet solar log base solarlog datenblatt solar log base

Manufacturer

Solar-Log GmbH
Fuhrmannstraße 9
72351 Geislingen-Binsdorf
Germany

Tel. / Fon: +49 (0) 7428 4089300
E.Mail: 
info@solar-log.com
Web: 
www.solar-log.com

Economic operator

Solar-Log GmbH
Fuhrmannstraße 9
72351 Geislingen-Binsdorf
Germany

Tel. / Fon: +49 (0) 7428 4089300
E.Mail: 
info@solar-log.com
Web: 
www.solar-log.com

Safety Instructions:

1. Installation by Qualified Personnel: The installation of smart meters must only be carried out by qualified electricians or authorized professionals.
2. Power Circuit Disconnection: Before installation, the power circuit into which the smart meter will be integrated must be completely disconnected and checked for powerlessness.
3. Ensure Proper Grounding: Verify the proper grounding of the system before connecting the smart meter.
4. Select Installation Location: Install the device only in a safe, well-ventilated, and dry indoor area that meets the manufacturer's installation requirements.
5. Correct Cable Connection: Use only manufacturer-recommended cables and connections, ensuring correct polarity and secure contacts.
6. Danger from High Voltages: Smart meters are integrated into power circuits that may be live. Avoid any contact with open connections or wires.
7. Use Proper Circuit Protection: Connect the smart meter only to power circuits with appropriate protective switches (e.g., residual current devices (RCDs) or circuit breakers).
8. Check Insulation: Inspect cable insulation and connection status before commissioning to avoid short circuits.
9. No Modifications: Do not alter or modify the smart meter or its wiring.
10. Avoid Overloading: Do not exceed the manufacturer's specified maximum current load for the smart meter.
11. No Unauthorized Modifications: Unauthorized alterations, modifications, repairs, or opening of the product are strictly prohibited.