€932.61
- Delivery time:
Currently out of stock, delivery time: 15-17 working days
- Item-No.: 114672
- Manufacturer-No.: ASH00131
- Product-Weight: 35 kg
- Shipping info: Spedition
Sungrow 8 kW Hybrid Inverter SH8.0RT-20-V11
Three-phase hybrid inverter with backup function, intelligent energy management and compact design – reliable and easy to install.
The Sungrow SH8.0RT-20-V11 is the three-phase hybrid inverter from the proven Sungrow SH-RT series for residential photovoltaic systems. It combines intelligent energy management, backup functionality and maximum ease of installation in a compact housing. With two independent MPP trackers, it can be flexibly deployed – even with different roof orientations or partial shading. The integrated backup function enables emergency power supply in the event of a grid failure with a near-seamless switchover in under 20 ms. The WiNet communication module and Smart Energy Meter are already included in the delivery – no additional meter required. The optional Sungrow iHomeManager extends the system with an AI-powered energy management system for wallbox control, heat pump integration and load management – recommended as soon as an EV or heat pump is involved.
Features
- Three-phase hybrid inverter: Ideal for residential PV systems with battery storage and self-consumption optimisation.
- 2 independent MPP trackers: Flexible DC design even with different roof areas or orientations.
- Backup function: Emergency power supply in the event of a grid failure – switchover in under 20 ms.
- Silent operation: Natural convection cooling without a fan – only 30 dB(A), ideal for indoor and outdoor installation.
- Optional Sungrow iHomeManager: AI-powered energy management system for wallbox control, heat pump integration and load management.
Included in Delivery
- Sungrow SH8.0RT-20-V11 hybrid inverter
- WiNet communication module
- Smart Energy Meter (3-phase)
| Technical Data | |
| Device type: | Three-phase hybrid inverter |
| Rated AC power: | 8.0 kW |
| Number of MPP trackers / DC inputs: | 2 / 2 (1 string per MPPT) |
| Max. DC input current per string: | 13.5 A (per MPPT) |
| Max. PV input voltage: | 1000 V |
| MPP voltage range: | 200 – 950 V |
| Grid connection: | 3~NPE 230/400 V, 50 Hz |
| Max. efficiency / European efficiency: | 98.4 % / 97.9 % |
| Protection class: | IP65 |
| Cooling: | Natural convection (fanless, 30 dB(A)) |
| Battery voltage: | 150 – 600 V |
| Max. charge/discharge current: | 30 A / 30 A |
| Compatible battery systems: | Sungrow SBR battery storage (150 – 600 V) |
| Backup function: | Yes – switchover time < 20 ms |
| Max. backup output power: | 8.0 kW / 8.0 kVA, peak 12.0 kW / 10 s |
| Surge protection: | DC Type II / AC Type II (integrated) |
| Mounting: | Indoor and outdoor installation (wall mounting) |
| Dimensions (W × H × D): | 460 × 540 × 170 mm |
| Weight: | 27 kg |
| Communication: | RS485, Wi-Fi, Ethernet, CAN |
| Optional accessories: | Sungrow iHomeManager, Sungrow Wallbox |
Further technical details can be found in the datasheet.

10 a.m. - 12 p.m. and
2 p.m. - 4 p.m.
- Photovoltaic experts since 2008
- Only original products from top brands
- Short response times to inquiries
- 2% discount for prepayment
- Short delivery times
- Collection of in-stock items possible
Safety Instructions:
- Installation by qualified personnel: Installation must only be carried out by qualified electricians or other qualified personnel.
- Work with the system switched off: Switch off all power sources (AC and DC) and verify that the system is de-energized before installation.
- Ensure grounding: The inverter and the entire system must be properly grounded to ensure safety.
- Ensure ventilation: Install the inverter in a well-ventilated location to prevent overheating. Observe the minimum clearances recommended by the manufacturer.
- No contact with flammable materials: The inverter must not be installed near flammable or explosive materials.
- High voltage hazard: Inverters operate at high DC and AC voltages. Do not touch any exposed wires or connectors.
- Use correct cables: Use only cables and connectors recommended or certified by the manufacturer.
- Observe polarity: Ensure the DC side is connected with correct polarity to avoid damage to the device.
- Do not work while connected: Never open or work on the inverter while it is live.
- Install surge protection: Protect the inverter and system from surges by installing surge protection devices and appropriate fuses.
- Ensure the device is de-energized: Before any maintenance or repair, all power sources must be disconnected and verified to be de-energized.
- No modifications: Unauthorized alterations, modifications, or repairs, as well as opening the product, are prohibited.
- Protect from water and moisture: Install the inverter in an environment protected from rain, condensation, and high humidity.
- Avoid dust and contamination: Keep the inverter free from dust, insects, and other contaminants.