€43.26
- Delivery time:
- Order number: 112920
- Weight: 0.238 kg
- EAN: 4262431422967
- Manufacturer's no.: 158-00000-02
- Collection possible: Self-Collection is currently not available.
in stock (7-14 working days) (abroad may vary)
Tigo Access Point (TAP) The Tigo Access Point (TAP) enables wireless communication between... more
Tigo Access Point (TAP)
The Tigo Access Point (TAP) enables wireless communication between Tigo Smart modules (e.g. TS4) and the monitoring system — significantly enhancing the data management of your solar installation. When paired with the Cloud Connect Advanced (CCA), the TAP allows module-level monitoring and control, including module-level rapid shutdown for increased safety.
Features:
- Wireless communication with TS4 modules (TS4-A-O, TS4-A-S, TS4-A-M)
- Easy, tool-free installation directly on the module frame
- Compatible with the Tigo SMART / EI app for quick commissioning
- Supports up to 300 TS4 units per TAP — suitable for small and large PV systems
- IP68 rated and weatherproof for outdoor use
- Enables module-level monitoring and UL-compliant rapid shutdown when used with CCA
| Technical Data | |
| Manufacturer Part Number: | 158-00000-02 |
| Ingress Protection: | IP68 / Type 4R |
| Dimensions: | 126.2 mm × 130.0 mm × 26.8 mm (with bracket) |
| Weight: | 227 g |
| Operating Temperature Range: | −30 °C to +70 °C |
| Input Voltage Range: | 5 V DC – 25 V DC |
| Max. Connected TS4 Modules: | Up to 300 TS4 units |
| Range (to nearest TS4): | Up to approx. 10 m, farthest up to approx. 35 m |
Please refer to the datasheet for further details.
Related links to "Tigo Energy Access Point (TAP)"
Produktsicherheits-Informationen anzeigen... more
Manufacturer:
2. Power Circuit Disconnection: Before installation, the power circuit into which the smart meter will be integrated must be completely disconnected and checked for powerlessness.
3. Ensure Proper Grounding: Verify the proper grounding of the system before connecting the smart meter.
4. Select Installation Location: Install the device only in a safe, well-ventilated, and dry indoor area that meets the manufacturer's installation requirements.
5. Correct Cable Connection: Use only manufacturer-recommended cables and connections, ensuring correct polarity and secure contacts.
6. Danger from High Voltages: Smart meters are integrated into power circuits that may be live. Avoid any contact with open connections or wires.
7. Use Proper Circuit Protection: Connect the smart meter only to power circuits with appropriate protective switches (e.g., residual current devices (RCDs) or circuit breakers).
8. Check Insulation: Inspect cable insulation and connection status before commissioning to avoid short circuits.
9. No Modifications: Do not alter or modify the smart meter or its wiring.
10. Avoid Overloading: Do not exceed the manufacturer's specified maximum current load for the smart meter.
11. No Unauthorized Modifications: Unauthorized alterations, modifications, repairs, or opening of the product are strictly prohibited.
Tigo Energy, Inc.
655 Campbell Technology Parkway Suite 150
Campbell, CA 95008
Vereinigte Staaten
https://tigoenergy.com/
Economic actor:Tigo Energy EMEA Büro
Tigo Energy Italien Srl Via Calamandrei 36
52025 Montevarchi Toskana
Italien
https://de.tigoenergy.com/contacts
Safety Instructions:
1. Installation by Qualified Personnel: The installation of smart meters must only be carried out by qualified electricians or authorized professionals.2. Power Circuit Disconnection: Before installation, the power circuit into which the smart meter will be integrated must be completely disconnected and checked for powerlessness.
3. Ensure Proper Grounding: Verify the proper grounding of the system before connecting the smart meter.
4. Select Installation Location: Install the device only in a safe, well-ventilated, and dry indoor area that meets the manufacturer's installation requirements.
5. Correct Cable Connection: Use only manufacturer-recommended cables and connections, ensuring correct polarity and secure contacts.
6. Danger from High Voltages: Smart meters are integrated into power circuits that may be live. Avoid any contact with open connections or wires.
7. Use Proper Circuit Protection: Connect the smart meter only to power circuits with appropriate protective switches (e.g., residual current devices (RCDs) or circuit breakers).
8. Check Insulation: Inspect cable insulation and connection status before commissioning to avoid short circuits.
9. No Modifications: Do not alter or modify the smart meter or its wiring.
10. Avoid Overloading: Do not exceed the manufacturer's specified maximum current load for the smart meter.
11. No Unauthorized Modifications: Unauthorized alterations, modifications, repairs, or opening of the product are strictly prohibited.
Folgende Infos zum Hersteller sind verfübar...... more
Tigo Energy
Tigo Energy is a global leader in Flex MLPE (Module Level Power Electronics), providing innovative solutions to increase energy production, improve safety and reduce operating costs of solar installations. Tigo''s TS4 platform provides customers with the industry''s most scalable, versatile and reliable MLPE solution. The company was founded in 2007 in Silicon Valley, California, to promote the global adoption of solar energy. Headquartered in Silicon Valley with a global presence, Tigo is well positioned internationally.
In stock
In stock
In stock
Discount
Discount
In stock
In stock
In stock
Discount
In stock
Discount
In stock
Discount
Discount
In stock
Left over
Discount
In stock
Left over
Discount
In stock
In stock
In stock
In stock
Tipp
In stock
Discount
In stock
Viewed