€157.16
- Delivery time:
In stock, delivery time: 3-5 days (varies for international orders)
- Item-No.: 113803
- GTIN: 4262431424039
- Manufacturer-No.: 12170142
- Product-Weight: 0.52 kg
- Shipping info: Paket
KOSTALl DC overvoltage protection module type 2 for PLENTICORE G3
The DC overvoltage protection module type 2 protects your PLENTICORE G3 from external overvoltage events. The optionally available DC surge protection module can be easily retrofitted in the inverter via Plug & Play.
Features:
- Made in Germany
- Protection against external overvoltage events
- Quick plug & play installation: simply plug in, no additional cabling required
- Triggering and failure detection via event messages on the inverter and via the KOSTAL Solar Portal and KOSTAL Solar App
| Specifications: | |
| Compatibility: | PLENTICORE G3 Series |
| Overvoltage protection type: | Type II |
| Number of DC inputs: | 3 |
| Mounting type: | Plug-in module in the inverter |
| Dimensions (L x W x D): | 150 x 65,4 x 30,5 mm |
| Weight: | 0,335 kg |
For further information, please refer to the data sheet.

10 a.m. - 12 p.m. and
2 p.m. - 4 p.m.
- Photovoltaic experts since 2008
- Only original products from top brands
- Short response times to inquiries
- 2% discount for prepayment
- Short delivery times
- Collection of in-stock items possible
Manufacturer
KOSTAL Solar Electric GmbH
Hanferstr. 6
79108 Freiburg i. Br.
Germany
Tel.: +49 (0) 761 47744 - 100
E-Mail: info-solar@kostal.com
Web: www.kostal-solar-electric.com
Economic operator
KOSTAL Solar Electric GmbH
Hanferstr. 6
79108 Freiburg i. Br.
Germany
Tel.: +49 (0) 761 47744 - 100
E-Mail: info-solar@kostal.com
Web: www.kostal-solar-electric.com
Safety Instructions:
- Installation by qualified personnel: Installation must only be carried out by qualified electricians or other qualified personnel.
- Work with the system switched off: Switch off all power sources (AC and DC) and verify that the system is de-energized before installation.
- Ensure grounding: The inverter and the entire system must be properly grounded to ensure safety.
- Ensure ventilation: Install the inverter in a well-ventilated location to prevent overheating. Observe the minimum clearances recommended by the manufacturer.
- No contact with flammable materials: The inverter must not be installed near flammable or explosive materials.
- High voltage hazard: Inverters operate at high DC and AC voltages. Do not touch any exposed wires or connectors.
- Use correct cables: Use only cables and connectors recommended or certified by the manufacturer.
- Observe polarity: Ensure the DC side is connected with correct polarity to avoid damage to the device.
- Do not work while connected: Never open or work on the inverter while it is live.
- Install surge protection: Protect the inverter and system from surges by installing surge protection devices and appropriate fuses.
- Ensure the device is de-energized: Before any maintenance or repair, all power sources must be disconnected and verified to be de-energized.
- No modifications: Unauthorized alterations, modifications, or repairs, as well as opening the product, are prohibited.
- Protect from water and moisture: Install the inverter in an environment protected from rain, condensation, and high humidity.
- Avoid dust and contamination: Keep the inverter free from dust, insects, and other contaminants.