KOSTAL BackUp Switch G3
With the KOSTAL BackUp Switch G3, you can continue to supply your home with electricity in the event of a power failure in combination with a PLENTICORE G3 series inverter, solar energy and a connected battery. To do this, the KOSTAL BackUp Switch G3 is installed in the building services and connected to the inverter. In the event of a power failure, you simply switch manually to the domestic grid and the inverter continues to supply you with energy.
Features:
- Made in Germany
- Manual three-phase mains changeover switch with position: Mains, standby and backup power
- Compatible with all inverters in the PLENTICORE G3 series
- Installation in existing sub-distribution board or in separate housing possible
- Suitable for house connections up to 63A
| Technische Daten: | |
| Manufacturer article description: | Backup Switch G3 |
| Compatibility: | PLENTICORE G3 Serie |
| Switching: | manually via rotary switch |
| Dimensions (L x W x D): | 144 x 102 x 97 mm |
| Weight: | 0,52 kg |
For further information, please refer to the data sheet.

10 a.m. - 12 p.m. and
2 p.m. - 4 p.m.
- Photovoltaic experts since 2008
- Only original products from top brands
- Short response times to inquiries
- 2% discount for prepayment
- Short delivery times
- Collection of in-stock items possible
Manufacturer
KOSTAL Solar Electric GmbH
Hanferstr. 6
79108 Freiburg i. Br.
Germany
Tel.: +49 (0) 761 47744 - 100
E-Mail: info-solar@kostal.com
Web: www.kostal-solar-electric.com
Economic operator
KOSTAL Solar Electric GmbH
Hanferstr. 6
79108 Freiburg i. Br.
Germany
Tel.: +49 (0) 761 47744 - 100
E-Mail: info-solar@kostal.com
Web: www.kostal-solar-electric.com
Safety Instructions:
- Installation by qualified personnel: Installation must only be carried out by qualified electricians or other qualified personnel.
- Work with the system switched off: Switch off all power sources (AC and DC) and verify that the system is de-energized before installation.
- Ensure grounding: The inverter and the entire system must be properly grounded to ensure safety.
- Ensure ventilation: Install the inverter in a well-ventilated location to prevent overheating. Observe the minimum clearances recommended by the manufacturer.
- No contact with flammable materials: The inverter must not be installed near flammable or explosive materials.
- High voltage hazard: Inverters operate at high DC and AC voltages. Do not touch any exposed wires or connectors.
- Use correct cables: Use only cables and connectors recommended or certified by the manufacturer.
- Observe polarity: Ensure the DC side is connected with correct polarity to avoid damage to the device.
- Do not work while connected: Never open or work on the inverter while it is live.
- Install surge protection: Protect the inverter and system from surges by installing surge protection devices and appropriate fuses.
- Ensure the device is de-energized: Before any maintenance or repair, all power sources must be disconnected and verified to be de-energized.
- No modifications: Unauthorized alterations, modifications, or repairs, as well as opening the product, are prohibited.
- Protect from water and moisture: Install the inverter in an environment protected from rain, condensation, and high humidity.