Fronius Smart Meter IP

The intelligent electricity meter with LAN and WLAN connection

The Fronius Smart Meter IP is a bidirectional meter for optimizing self-consumption and recording the household's load curve. Together with the Fronius inverter, the Fronius Datamanager and the Fronius data interface, the Fronius Smart Meter IP provides a clear overview of your own power consumption. The meter measures the power flow to the consumers or to the grid and forwards the information to the Fronius inverter and the Fronius Datamanager via Modbus RTU/RS485 or TCP (LAN/WLAN) communication.

Please note: The Fronius Smart Meter IP is only compatible with Fronius Tauro and Fronius GEN24 inverters.

Technical data IP
Inverter compatibility: Fronius GEN24, Fronius Tauro
Nominal voltage: 100 - 240 V
Operating voltage range: -10% bis +10%
Nominal frequency: 50 - 60 Hz
Maximum current: 5000 A
Starting current: 20 (max. 30) mA

For further details, please refer to the data sheet.

 

Related links to "Fronius Smart Meter IP"
Produktsicherheits-Informationen anzeigen... more
Manufacturer:

Fronius International GmbH
Froniusstraße 1
4643 Pettenbach
Österreich

contact@fronius.com
www.fronius.com

Economic actor:

Fronius Deutschland GmbH
Fronius Straße 1
36119 Neuhof-Dorfborn
Deutschland

pv-sales-germany@fronius.com
www.fronius.com/de-de

Safety Instructions:

1. Installation by Qualified Personnel: The installation of smart meters must only be carried out by qualified electricians or authorized professionals.
2. Power Circuit Disconnection: Before installation, the power circuit into which the smart meter will be integrated must be completely disconnected and checked for powerlessness.
3. Ensure Proper Grounding: Verify the proper grounding of the system before connecting the smart meter.
4. Select Installation Location: Install the device only in a safe, well-ventilated, and dry indoor area that meets the manufacturer's installation requirements.
5. Correct Cable Connection: Use only manufacturer-recommended cables and connections, ensuring correct polarity and secure contacts.
6. Danger from High Voltages: Smart meters are integrated into power circuits that may be live. Avoid any contact with open connections or wires.
7. Use Proper Circuit Protection: Connect the smart meter only to power circuits with appropriate protective switches (e.g., residual current devices (RCDs) or circuit breakers).
8. Check Insulation: Inspect cable insulation and connection status before commissioning to avoid short circuits.
9. No Modifications: Do not alter or modify the smart meter or its wiring.
10. Avoid Overloading: Do not exceed the manufacturer's specified maximum current load for the smart meter.
11. No Unauthorized Modifications: Unauthorized alterations, modifications, repairs, or opening of the product are strictly prohibited.